Karl Fischer Instrument
  • Karl Fischer InstrumentKarl Fischer Instrument
  • Karl Fischer InstrumentKarl Fischer Instrument
  • Karl Fischer InstrumentKarl Fischer Instrument

Karl Fischer Instrument

Karl Fischer Instrument is a classical titration method in chemical analysis. It uses coulometric titration or volumetric titration to determine trace water in samples. It was invented by German chemist Karl Fisher in 1935. Today, the titration is done with Karl Fischer automatic titrator. Weshine® The developed Karl Fischer Instrument (KF titrator) introduces the reliable performance, simple operation and space saving design of the compact KF coulometer. The accurate result is 1 ppm to 5% water. Each user can have up to 4 shortcuts + 5 analysis methods. With the Weshine® Karl Fischer Instrument, the operator can conduct moisture measurement by pressing the button! Contact us for more details on winding resistance testing of Weshine Karl Fischer Instrument.

Send Inquiry    PDF DownLoad

Product Description


Karl Fischer Instrument

 

Karl Fischer Instrument, also known as KF titrator, is used to determine the amount of water in the sample. Since the presence of water affects many characteristics of products, including reactivity, stability and quality, KF titration is very important in many industries and is used in many industries. The food, petroleum, pharmaceutical and semiconductor industries use Karl Fischer Instrument to maintain product quality. There are two kinds of Karl Fischer Instrument methods: volumetric method, which uses the amount of reagent to determine the amount of water; The coulometric method of electrolytic reaction uses electricity to tell us the amount of water in the sample. The volumetric method is suitable for the measurement of water from 1 to 100 mg, while the coulometric method is suitable for very small amounts of water from 10 micrograms to 10 mg. When selecting a suitable Karl Fischer Instrument, several factors should be considered, including the size of the sample required, whether volumetric titration or coulometric titration is required, the time required for titration, the degree of automation in the process, and the amount of labor required.

 

Weshine® Karl Fischer Instrument Parameter (Specification)

 

PRODUCT INFORMATION

Product Name

KARL FISCHER INSTRUMENT

Test Range

1 μg ~ 200 mg

Power

<40W

Electrolytic Current

0~400 mA automatic control

Titration method

Coulometric titration(Coulomb analysis)

Accuracy

10 µg~1000 µg ±3 µg

More than 1 mg but not greater than 0.3%

Standards

GB/T11133,ASTM D1744,DIN 51777

Certificates

CE; EMC; LVD; ISO; IEC;

Dimensions

380 x 310 x 180 mm

Model Number

VS-9805

 

One Click User Interface

With the intuitive One Click touchscreen interface, customize home screens to run your workflows quickly and easily with a single tap on the screen.

 

Karl Fischer Titration

Excellence line titrators fully support both volumetric and coulometric Karl Fischer titrations to accurately measure water in liquid or solid samples from 0.001% to 100%.

 

Plug & Play Accessories

Sensors and burettes are automatically recognized when connected. Avoid errors by eliminating extra data entry steps and reduce instrument setup time.

 


 


Selections

 

Weshine has 8 years experience specifically for deal with complete range of Electrical Equipment. At present, Weshine has invented various Karl Fischer Instrument as shown as form:

 

ORDERING INFORMATION FOR KARL FISCHER INSTRUMENT

Cat. No.

Test Current
 (mA)

Test Range

Accuracy

Dimensons
(mm)

Weight
(kg)

VS-9805

0 to 400

3 μg to 100 mg

±3 μg≤1 mg,

<3%>1 mg

320 x 235 x 150

4.5

VS-9805A

0 to 400

1 μg to 200 mg

380 x 310 x 180

4

Based on Supply Chain issues: Please contact your preferred Authorized Weshine Distributor for current pricing and lead times.

 

Quality Certificates

 

We always believe that all the success of our company is directly related to the quality of the products we provide. Karl Fischer Instrument meet the highest quality requirements specified in ISO9001, ISO14000:14001 guidelines and our strict quality control system.


 

Shipment 


 


For further information on Weshine's Service Solutions, contact our 24/7 online sales representative to get quotes from Weshine.


Contact us


FEEL FREE TO MAKE A PHONE CALL:400 996 1868

OR E-MAIL TO: info@weishengelectric.com

SALES OFFICE

Weshine Limited 602, Building 3, Diangu

Technology Center, No. 3088, Lekai North Street

W/app: +86 1873 1260 588

E. info@weishengelectric.com

sale01@weishengelectric.com


CONTACT OFFICE

T. 0312 3188565

E. bdweisheng@weishengelectric.com


AFTER-SALES SERVICE

T. +86 157 1252 6062


Hot Tags: Karl Fischer Instrument, Buy, China, Manufacturers, Suppliers, Factory, Price, Purpose, Specification, Results, Definition
Related Category
Send Inquiry
Please feel free to give your inquiry in the form below. We will reply you in 24 hours.
X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
Reject Accept