Weshine is New Brand and Fast rising in Gas Chromatography for Dissolved Gas Analysis of Transformer Oil. Relying on High-Quality product and Efficient after-sales service to win the trust of the customers. Weshine is your trusted manufacturer and supplier in China. Our Gas Chromatography for Dissolved Gas Analysis of Transformer Oil can help you to do the gas analysis works very well, especially the after-sales service is Excellent. Looking forward to have a good and long partnership with you.

Send Inquiry

Product Description

Gas Chromatography for Dissolved Gas Analysis of Transformer Oil


Product Introduction:

Weshine VS-9808 Gas Chromatography for Dissolved Gas Analysis of Transformer Oil specializes in the analysis of gases in transformer insulating oil. The Gas Chromatography for Dissolved Gas Analysis of Transformer Oil can analyze 7/9/11 kinds of gas components in the insulating oil through two or three chromatographic columns. If there are many oil samples needed to be tested, then the Headspace Autosampler can help to extract the gases from the oil for the Gas Chromatography for Dissolved Gas Analysis of Transformer Oil. 27/72 Samples can be shocked and heated, and then transmit the gases automatically by the Autosampler. It can help the Gas Chromatography for Dissolved Gas Analysis of Transformer Oil a lot, and save labor cost and time cost. The software of the Gas Chromatography for Dissolved Gas Analysis of Transformer Oil is easy to operate, we can provide online video guidance and remote assistance. Please enjoy our 7days*24hours after-sales service.


Product Parameter:

Operating display

192*64 periodic lattice liquid crystal

Temperature control area

6 ways

Temperature

5℃~ 400℃

Programming

Rate 0. 1 ~ 39℃/min

External events

4 ways

Detector

FID, TCD, ECD, FPD and NPD

Communication interface

Ethernet: IEEE802. 3


Product Feature:

Gas Chromatography for Dissolved Gas Analysis of Transformer Oil mainly analysis the gases components from the transformer insulating oil. Gas Chromatography for Dissolved Gas Analysis of Transformer Oil works with the Air Generator, Hydrogen Generator, and Oscillator.

The Oscillator shocks and heats up the oil sample to get the gas from the oil. And then inject the gas sample into the Gas Chromatography for Dissolved Gas Analysis of Transformer Oil. Before that, we should use the Air Generator and Hydrogen Generator to fire the FID1 and FID2. The Gas Chromatography for Dissolved Gas Analysis of Transformer Oil will analysis the gas sample automatically, and you will see the gases components waves on the software on PC. The test report can be printed by the printer from the Gas Chromatography for Dissolved Gas Analysis of Transformer Oil.


Product details:




For Headspace Sampler:

The Autosampler can extracts the gases from the insulating oils, and transmit the gases by carrier gas to the Gas Chromatography for Dissolved Gas Analysis of Transformer Oil Columns. It has the function of the heating and shocking, instead of the manual oscillator.


Details of the Vials

Number of vials

27/72

Vial Material

Neutral Glass

Vial volume

20ml

Vial Septum

PTFE coated with butene rubber

PTFE coated with silicone rubber

Vial Aluminum Cap

Aluminum


For Oscillator:


The Oscillator heats and shocks the transformer oil to extract the gases from the transformer insulating oils automatically. The temperature and times can be set. Put the 40ml oils into the 100ml-injector, and then put 8 injectors at max into the oscillator to start the extraction works.


For Hydrogen Generator:

This Hydrogen Generator make the hydrogen for the Gas Chromatography for Dissolved Gas Analysis of Transformer Oil, the hydrogen can help to fire the FID1 and FID2.


For the Air Generator:

The Air Generator provides the air for the Gas Chromatography for Dissolved Gas Analysis of Transformer Oil to help the Hydrogen firing.


Quality Certificates

We always believe that all the success of our company is directly related to the quality of the products we provide. Oil BDV Tester forDielectric Test of Transformer Oilmeet the highest quality requirements specified in ISO9001, ISO14000:14001 guidelines and our strict quality control system.


Shipment

For further information on Weshine®'s Service Solutions, contact our 24/7 online sales representative to get quotes from Weshine®.


Contact us


FEEL FREE TO MAKE A PHONE CALL:400 996 1868

OR E-MAIL TO: info@weishengelectric.com

SALES OFFICE

Weshine Limited 602, Building 3, Diangu

Technology Center, No. 3088, Lekai North Street

W/app: +86 1873 1260 588

E. info@weishengelectric.com

sale01@weishengelectric.com


CONTACT OFFICE

T. 0312 3188565

E. bdweisheng@weishengelectric.com


AFTER-SALES SERVICE

T. +86 157 1252 6062




Hot Tags: Dissolved Gas Analysis of Transformer Oil, Buy, China, Manufacturers, Suppliers, Factory, Price, Purpose, Specification, Results, Definition
Related Category
Send Inquiry
Please feel free to give your inquiry in the form below. We will reply you in 24 hours.
X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
Reject Accept