Buy quality Automatic Karl Fischer Moisture Tester from Weshine, a professional Karl Fischer Titration manufacturer in China. It accurately measures trace moisture in transformer oil, lubricants, chemicals and pharmaceuticals via coulometric titration. Fully automatic and highly repeatable, it comes with LCD display, auto endpoint detection, printer and stirrer for routine QC labs in power, petrochemical and pharmaceutical industries.
Weshine factory's durable automatic Karl Fischer moisture tester is a common analytical device built for trace water detection, following the globally recognized coulometric Karl Fischer titration standard. This testing method delivers outstanding sensitivity, making it the go-to choice for measuring ultra-low water content inside insulating oil, petrochemical products, organic solvents and liquid chemical samples.
The machine handles electrolyte balance, titration, endpoint judgment, data calculation and result display all on its own, requiring little manual operation. Stable electrolytic current and fast response bring highly consistent test data batch after batch.
A high-definition LCD screen shows a straightforward operation interface, so operators can adjust test parameters and watch the whole titration process in real time. The internal magnetic stirrer mixes samples evenly, boosting electrolysis efficiency and reading accuracy.
The full titration assembly includes electrolytic cell, measuring electrode, electrolysis electrode, drying tube, sample injection port and stirring component. Premium glass parts resist chemical corrosion and block ambient moisture from interfering with test data.
It is widely adopted by power plant labs, transformer factories, petrochemical workshops, pharmaceutical manufacturers, research institutes and third-party inspection labs, offering quick and reliable moisture detection for routine lab checks and factory quality control.
|
Measurement Specifications |
Display & Operation |
Power Supply |
|||
|
Parameter |
Specification |
Parameter |
Specification |
Parameter |
Specification |
|
Measurement Method |
Karl Fischer Coulometric Titration |
Display |
LCD Screen |
Power Supply |
AC220V ±10%, 50Hz |
|
Measuring Range |
1 μg – 200 mg H₂O |
Operation |
Automatic |
Power Consumption |
≤40W |
|
Resolution |
0.1 μg |
Stirring System |
Built-in Magnetic Stirrer |
|
|
|
Sensitivity |
0.1 μg H₂O |
Result Display |
Automatic Calculation |
|
|
|
Accuracy |
±(2 μg – 5 μg) Typical |
Sample Injection |
Syringe Injection |
|
|
|
Electrolysis Control |
Automatic |
|
|
|
|
|
Endpoint Detection |
Automatic |
|
|
|
|
|
Environmental Conditions |
|
|
|
|
Parameter |
Specification |
Parameter |
Specification |
|
Operating Temperature |
5°C – 40°C |
Weight |
5.8 kg |
|
Relative Humidity |
≤80% RH |
Dimensions (L × W × H) |
380 × 290 × 180 mm |
This quality Automatic Karl Fischer Moisture Tester runs on coulometric Karl Fischer reaction rules. After injecting liquid samples into the sealed titration cell, water molecules inside the sample will quantitatively react with Karl Fischer reagent.
During electrolysis, iodine is produced automatically to combine with water. Once all moisture fully reacts, the machine immediately catches the endpoint, calculates water content and shows final readings without manual math work.
The built-in magnetic stirrer keeps samples and electrolyte fully mixed, maintaining stable electrolytic conditions and reliable repeated test results.
1.Standard coulometric Karl Fischer titration technology
2.Full automatic trace moisture measurement workflow
3.High precision for tiny water content detection
4.Auto electrolysis parameter adjustment
5.Intelligent endpoint auto-detection
6.Large clear LCD operation screen
7.Integrated magnetic stirring component
8.Auto computation of water content value
9.Short single-test cycle
10.Stable repeatable test data
11.Low consumption of Karl Fischer reagent
12.High testing sensitivity
13.Steady electrolytic current control
14.Simple manual sample injection
15.Corrosion-resistant glass titration cell
16.Perfect for trace water testing scenarios
17.Easy learning operation logic
18.Stable long-term lab use performance
Test trace moisture inside transformer insulating oil and other electrical insulating liquids for daily equipment maintenance.
Carry out incoming quality inspection for brand-new insulating oil before transformer assembly and delivery.
Detect water content of lubricants, hydraulic oil, fuel oil and all kinds of petroleum finished products.
Measure moisture index of organic solvents, liquid chemical raw materials and intermediate reagents.
Complete trace moisture testing for pharmaceutical raw materials and liquid pharmaceutical products.
Support high-precision trace water analysis for scientific research and experimental projects.
1.Transformer insulating oil moisture detection
2.Electrical insulation liquid water content test
3.Industrial lubricant moisture measurement
4.Hydraulic oil trace water analysis
5.General petroleum product water testing
6.Organic chemical solvent moisture inspection
7.Various organic liquid water content testing
8.Pharmaceutical raw material moisture analysis
9.Lab daily quality control testing
10.Industrial raw material regular inspection
A regional power station needed stable, accurate trace moisture readings for transformer oil during regular maintenance, to avoid insulation breakdown and unexpected equipment faults.
The team deployed our Automatic Karl Fischer Moisture Tester. Field technicians get precise trace water data rapidly with good repeatability, supporting scientific maintenance scheduling.
1.Fast, credible on-site moisture test results
2.Improved overall transformer running stability
3.Lower hidden equipment failure risks
4.Greatly boosted daily lab testing efficiency
Weshine Electric focuses on R&D and manufacturing transformer testing instruments and electrical analysis equipment. Our test equipment series integrate high-precision sensors, automatic control logic, portable structure and complete data export functions, supplying dependable electrical testing solutions for power operators, transformer manufacturers, service teams and third-party labs worldwide.
1、What can this tester measure?
It accurately determines trace moisture in transformer oil, lubricating oil, hydraulic oil, petroleum products, chemical reagents, and other industrial liquids.
2、Why use Karl Fischer titration?
Karl Fischer titration is the industry-standard method for trace moisture analysis, providing excellent accuracy, sensitivity, and repeatability.
3、Is it suitable for transformer oil testing?
Yes. It is widely used by power utilities, transformer manufacturers, electrical laboratories, and maintenance companies for insulating oil moisture analysis.
4、Does the instrument operate automatically?
Yes. It automatically performs electrolysis, endpoint detection, moisture calculation, and result display, minimizing operator intervention.
5、Why is moisture testing important?
Regular moisture testing helps maintain insulation performance, extend transformer service life, reduce failure risks, and support preventive maintenance.
|
FEEL FREE TO MAKE A PHONE CALL:400 996 1868 |
OR E-MAIL TO: info@weishengelectric.com |
|
SALES OFFICE Weshine Limited 602, Building 3, Diangu Technology Center, No. 3088, Lekai North Street W/app: +86 1873 1260 588 E. info@weishengelectric.com sale01@weishengelectric.com |
CONTACT OFFICE T.0312 3188565 E. bdweisheng@weishengelectric.com
AFTER-SALES SERVICE T. +86 157 1252 6062 |